{"id":105238,"date":"2025-02-17T19:14:45","date_gmt":"2025-02-17T19:14:45","guid":{"rendered":"https:\/\/yulgary.de\/?post_type=product&#038;p=105238"},"modified":"2026-01-15T16:36:40","modified_gmt":"2026-01-15T16:36:40","slug":"umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950","status":"publish","type":"product","link":"https:\/\/yulgary.de\/?product=umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950","title":{"rendered":"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950"},"content":{"rendered":"<p>Die <strong>umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950<\/strong> ist ein fortschrittliches Instrument, das entwickelt wurde, um die genauen Umweltbedingungen zu reproduzieren, die f\u00fcr umfassende pharmazeutische Stabilit\u00e4tsbewertungen erforderlich sind. Diese hochmoderne Kammer ist unverzichtbar f\u00fcr die \u00dcberwachung der Wirkstoffabbau \u00fcber die Zeit, die Beschleunigung von Testprozessen und die Durchf\u00fchrung von Langzeitexperimenten. Ideal f\u00fcr Pharmaunternehmen und Forschungslabore, ist die YG0948 \/\/ YG0950 hervorragend geeignet f\u00fcr Stabilit\u00e4tsstudien an Arzneimitteln, die eine hohe Luftfeuchtigkeit und starke Lichteinwirkung erfordern, und sorgt f\u00fcr \u00e4u\u00dferst genaue und zuverl\u00e4ssige Ergebnisse.<\/p>\n<h2>Marktpreis<\/h2>\n<p>Im Premiumsegment positioniert liegt die <strong>umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950<\/strong> typischerweise im Preisbereich von 6.548 bis 10.882 USD. Preisvariationen h\u00e4ngen von der Konfiguration und optionalen Upgrades wie Fern\u00fcberwachungssoftware und Mehrfacheinheitenkonnektivit\u00e4t ab. Ihre pr\u00e4zise Konstruktion, Energieeffizienz und vielseitige Umweltkontrollen machen sie zu einer erheblichen Investition f\u00fcr Einrichtungen, die sich der pharmazeutischen Forschung und Stabilit\u00e4tspr\u00fcfung widmen.<\/p>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<ul>\n<li><strong>Welche Branchen profitieren von der YG0948 \/\/ YG0950 Kammer?<\/strong><br \/>Diese Kammer bietet erheblichen Nutzen f\u00fcr die pharmazeutische, biotechnologische, Lebensmittel- und Lebenswissenschaftssektoren. Sie ist entscheidend f\u00fcr die Pr\u00fcfung der Stabilit\u00e4t neuer Wirkstoffformulierungen, pharmazeutischer Produkte und anderer Substanzen, die empfindlich auf Umweltfaktoren wie Temperatur und Licht reagieren.<\/li>\n<li><strong>Wie vergleicht sich die YG0948 \/\/ YG0950 mit anderen Stabilit\u00e4tspr\u00fcfkammern?<\/strong><br \/>Diese Kammer bietet au\u00dfergew\u00f6hnliche Kontrolle \u00fcber Temperatur, Luftfeuchtigkeit und Licht mit fortschrittlichen Funktionen wie programmierbarer PID-Regelung, ALLFLOW-Luftstromkreis und einem effizienten K\u00fchlsystem. Sie gew\u00e4hrleistet konsistente und reproduzierbare Ergebnisse, indem sie genaue Umweltbedingungen sowohl f\u00fcr Langzeitbeurteilungen als auch beschleunigte Tests aufrechterh\u00e4lt.<\/li>\n<li><strong>Unterst\u00fctzt diese Kammer die Fern\u00fcberwachung und -steuerung?<\/strong><br \/>Ja, die YG0948 \/\/ YG0950 bietet optionale Software, die die Fernsteuerung \u00fcber Computer erm\u00f6glicht, sodass Echtzeitdaten\u00fcberwachung und -verwaltung mehrerer Einheiten gleichzeitig m\u00f6glich ist.<\/li>\n<\/ul>\n<h2>Vor- und Nachteile<\/h2>\n<p><strong>Vorteile:<\/strong><\/p>\n<ul>\n<li>Hochpr\u00e4zise Umweltsteuerung f\u00fcr genaue Stabilit\u00e4tspr\u00fcfungen von Arzneimitteln.<\/li>\n<li>Energieeffizientes Design mit fortschrittlicher K\u00e4ltetechnik und umweltfreundlichen K\u00e4ltemitteln.<\/li>\n<li>Programmierbare Mehrabschnittssteuerung erm\u00f6glicht ma\u00dfgeschneiderte Testzyklen und bietet Flexibilit\u00e4t.<\/li>\n<li>Benutzerfreundliche Schnittstelle mit Punkt-Matrix-LCD-Display und Echtzeit\u00fcberwachung.<\/li>\n<li>Effektive Luftzirkulations- und Feuchtigkeitskontrollsysteme gew\u00e4hrleisten konsistente Ergebnisse.<\/li>\n<\/ul>\n<p><strong>Nachteile:<\/strong><\/p>\n<ul>\n<li>Hohe Preisklasse kann f\u00fcr kleinere Labors mit begrenztem Budget die Zug\u00e4nglichkeit einschr\u00e4nken.<\/li>\n<li>Regelm\u00e4\u00dfige Wartung erforderlich, um optimale Leistung sicherzustellen, einschlie\u00dflich Kalibrierung der Sensoren und \u00dcberpr\u00fcfung der K\u00e4ltemittel.<\/li>\n<li>Kann w\u00e4hrend kontinuierlicher Langzeittestungen einen h\u00f6heren Energieverbrauch haben.<\/li>\n<\/ul>\n<h2>Anwendungsbereiche<\/h2>\n<p>Die YG0948 \/\/ YG0950 ist ideal f\u00fcr die Durchf\u00fchrung beschleunigter Stabilit\u00e4tspr\u00fcfungen, Langzeitversuche und Pr\u00fcfungen unter hoher Feuchtigkeit von pharmazeutischen Produkten. Sie spielt eine entscheidende Rolle im Arzneimittelentwicklungsprozess, indem sie die Auswirkungen von Umweltbelastungen auf die Produktintegrit\u00e4t bewertet und die Einhaltung von Vorschriften zur Lebensdauer und Stabilit\u00e4t sicherstellt.<\/p>\n<h2>Empfehlungen<\/h2>\n<p>F\u00fcr optimale Leistung der <strong>umfassenden Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950<\/strong> wird regelm\u00e4\u00dfige Wartung empfohlen, einschlie\u00dflich routinem\u00e4\u00dfiger Kalibrierung der Sensoren und \u00dcberpr\u00fcfung der K\u00e4ltemittel. Die Verwendung der Fern\u00fcberwachungssoftware erh\u00f6ht die Betriebseffizienz durch Echtzeitdatenanalyse und Verwaltung mehrerer Einheiten. Erw\u00e4gen Sie die Nutzung dieser F\u00e4higkeiten, um Ihre Forschungsergebnisse zu verbessern.<\/p>\n<h2>Eigenschaften<\/h2>\n<ul>\n<li>Erzwungene Konvektion<\/li>\n<li>Drei\u00dfig-Stufen-Mikroprozessor-PID-Regler<\/li>\n<li>Temperaturbereich: 10~65\u2103 (mit Beleuchtung) \/ 0~60\u2103 (ohne Beleuchtung)<\/li>\n<li>Feuchtigkeitsbereich: 50~90% RH, Feuchtigkeitsschwankung: \u00b13% RH<\/li>\n<li>Beleuchtungsbereich: 0~6000 LX (f\u00fcnf Stufen einstellbar)<\/li>\n<\/ul>\n<h2>Technische Spezifikationen<\/h2>\n<table>\n<tbody>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Produktmodell<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"203\">\n<div align=\"center\">\n<p><strong>ALLIGENT-KG<\/strong><\/p>\n<p><strong>Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer<\/strong><\/p>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div><\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\"><strong>YG0948<\/strong><\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\"><strong>YG0949<\/strong><\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\"><strong>YG0950<\/strong><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Konvektionsmodus<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">Erzwungene Konvektion<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Steuerungssystem<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"621\">\n<div align=\"center\">Drei\u00dfig-Stufen-Mikroprozessor-PID-Regler<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Temp.-Bereich<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"200\">\n<div align=\"center\">10~65\u2103(mit Beleuchtung)\/0~60\u2103(ohne Beleuchtung)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Temp.-Genauigkeit<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">0,1\u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\">\n<p><strong>Temp.-Schwankung<\/strong><\/p>\n<p><strong>\uff0810-40\u2103\uff09<\/strong><\/p>\n<\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">\u00b10,5\u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"142\">\n<div align=\"center\"><strong>Temp.-Einheitlichkeit\uff0810-40\u2103\uff09<\/strong><\/div>\n<\/td>\n<td align=\"center\" valign=\"top\" width=\"225\">\n<div align=\"center\">\u00b11<\/div>\n<\/td>\n<td align=\"center\" valign=\"top\" width=\"245\">\n<div>\u00b11<\/div>\n<\/td>\n<td align=\"center\" valign=\"top\" width=\"225\">\n<div>\u00b11,5<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Feuchtigkeitsbereich<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"200\">\n<div align=\"center\">Feuchtigkeitsbereich\uff1a50~90%RH\uff0cFeuchtigkeitsschwankung\uff1a\u00b13%RH<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Beleuchtungsbereich<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"200\">\n<div align=\"center\">0~6000LX\uff08f\u00fcnf Stufen einstellbar\uff09<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Arbeitsumgebung<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">Umgebungstemperatur\uff1a10~30\u2103, Luftfeuchtigkeit\u00a0&lt;70%<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Isoliermaterialien<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">Importiertes umweltschonendes Material<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Externe Abmessungen (H\u00d7B\u00d7T)<\/strong><\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">1410\u00d7650\u00d7680<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">1730\u00d7650\u00d7740<\/div>\n<\/td>\n<td valign=\"center\" width=\"64\">\n<div align=\"center\">1700\u00d7745\u00d7930<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Interne Abmessungen (H\u00d7B\u00d7T)<\/strong><\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">760\u00d7510\u00d7390<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">1100\u00d7510\u00d7450<\/div>\n<\/td>\n<td valign=\"center\" width=\"64\">\n<div align=\"center\">1050\u00d7600\u00d7640<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div><strong>Innenvolumen (L)<\/strong><\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\">150<\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\">250<\/div>\n<\/td>\n<td valign=\"top\" width=\"64\">\n<div align=\"center\">400<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"135\">\n<div align=\"center\"><strong>Innenstahlmaterialien<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"621\">\n<div align=\"center\">Innenstahlmaterialien<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div align=\"center\"><strong>Leistungsaufnahme\u00a0(W)<\/strong><\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">1080<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">1100<\/div>\n<\/td>\n<td valign=\"center\" width=\"64\">\n<div align=\"center\">1350<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div><strong>Stromversorgung<\/strong><\/div>\n<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"621\">\n<div align=\"center\">AC220V\/50Hz<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div><strong>Nettogewicht (KG)<\/strong><\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">107<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">135<\/div>\n<\/td>\n<td valign=\"center\" width=\"64\">\n<div align=\"center\">158<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div>Versandgewicht (KG)<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">132<\/div>\n<\/td>\n<td valign=\"center\" width=\"67\">\n<div align=\"center\">162<\/div>\n<\/td>\n<td valign=\"center\" width=\"64\">\n<div align=\"center\">186<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"135\">\n<div>Versandabmessungen\u00a0(H\u00d7B\u00d7T)<\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\">1610\u00d7750\u00d7830<\/div>\n<\/td>\n<td valign=\"top\" width=\"67\">\n<div align=\"center\">1930\u00d7750\u00d7890<\/div>\n<\/td>\n<td valign=\"top\" width=\"64\">\n<div align=\"center\">1900\u00d7840\u00d71080<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p><strong>Hersteller: <\/strong><strong><em>YUL GARY<\/em><\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-29188\" src=\"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/09\/CE.jpg\" alt=\"\" width=\"54\" height=\"53\" \/><\/p>\n","protected":false},"featured_media":105213,"template":"","meta":[],"product_brand":[],"product_cat":[2405],"product_tag":[],"class_list":["post-105238","product","type-product","status-publish","has-post-thumbnail","product_cat-umfassende-arzneimittel-stabilitatsprufkammern","first","instock","taxable","shipping-taxable","purchasable","product-type-variable"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary<\/title>\n<meta name=\"description\" content=\"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary\" \/>\n<meta property=\"og:description\" content=\"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/\" \/>\n<meta property=\"og:site_name\" content=\"Yul Gary\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-15T16:36:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"790\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/\",\"url\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/\",\"name\":\"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary\",\"isPartOf\":{\"@id\":\"https:\/\/yulgary.de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg\",\"datePublished\":\"2025-02-17T19:14:45+00:00\",\"dateModified\":\"2026-01-15T16:36:40+00:00\",\"description\":\"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...\",\"breadcrumb\":{\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage\",\"url\":\"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg\",\"contentUrl\":\"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg\",\"width\":790,\"height\":450},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/yulgary.de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/yulgary.de\/operation-lamp-yr02106-yr02112\/operation-lamp-yr02106-yr02112-yr02109\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/yulgary.de\/#website\",\"url\":\"https:\/\/yulgary.de\/\",\"name\":\"Yul Gary\",\"description\":\"Hergestellt und exportiert mit Hingabe, bietet unser Unternehmen hochwertige Laborger\u00e4te f\u00fcr eine lange Lebensdauer.\",\"publisher\":{\"@id\":\"https:\/\/yulgary.de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/yulgary.de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/yulgary.de\/#organization\",\"name\":\"Kalstein Chile\",\"url\":\"https:\/\/yulgary.de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/yulgary.de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/yulgary.de\/wp-content\/uploads\/2019\/11\/Perfil_KALSTEIN.png\",\"contentUrl\":\"https:\/\/yulgary.de\/wp-content\/uploads\/2019\/11\/Perfil_KALSTEIN.png\",\"width\":600,\"height\":600,\"caption\":\"Kalstein Chile\"},\"image\":{\"@id\":\"https:\/\/yulgary.de\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary","description":"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/","og_locale":"de_DE","og_type":"article","og_title":"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary","og_description":"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...","og_url":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/","og_site_name":"Yul Gary","article_modified_time":"2026-01-15T16:36:40+00:00","og_image":[{"width":790,"height":450,"url":"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/","url":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/","name":"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950 - Yul Gary","isPartOf":{"@id":"https:\/\/yulgary.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage"},"image":{"@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage"},"thumbnailUrl":"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg","datePublished":"2025-02-17T19:14:45+00:00","dateModified":"2026-01-15T16:36:40+00:00","description":"Die umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0947 \/\/ YG0950 ist eine Hochleistungs-Umwelttestl\u00f6sung, die speziell entwickelt wurde...","breadcrumb":{"@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#primaryimage","url":"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg","contentUrl":"https:\/\/yulgary.de\/wp-content\/uploads\/2025\/02\/YG0944.jpg","width":790,"height":450},{"@type":"BreadcrumbList","@id":"https:\/\/yulgary.de\/produkt\/umfassende-arzneimittelstabilitatsprufkammer-yg0948-yg0950\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/yulgary.de\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/yulgary.de\/operation-lamp-yr02106-yr02112\/operation-lamp-yr02106-yr02112-yr02109\/"},{"@type":"ListItem","position":3,"name":"Umfassende Arzneimittelstabilit\u00e4tspr\u00fcfkammer YG0948 \/\/ YG0950"}]},{"@type":"WebSite","@id":"https:\/\/yulgary.de\/#website","url":"https:\/\/yulgary.de\/","name":"Yul Gary","description":"Hergestellt und exportiert mit Hingabe, bietet unser Unternehmen hochwertige Laborger\u00e4te f\u00fcr eine lange Lebensdauer.","publisher":{"@id":"https:\/\/yulgary.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yulgary.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/yulgary.de\/#organization","name":"Kalstein Chile","url":"https:\/\/yulgary.de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/yulgary.de\/#\/schema\/logo\/image\/","url":"https:\/\/yulgary.de\/wp-content\/uploads\/2019\/11\/Perfil_KALSTEIN.png","contentUrl":"https:\/\/yulgary.de\/wp-content\/uploads\/2019\/11\/Perfil_KALSTEIN.png","width":600,"height":600,"caption":"Kalstein Chile"},"image":{"@id":"https:\/\/yulgary.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/yulgary.de\/index.php?rest_route=\/wp\/v2\/product\/105238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yulgary.de\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yulgary.de\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yulgary.de\/index.php?rest_route=\/wp\/v2\/media\/105213"}],"wp:attachment":[{"href":"https:\/\/yulgary.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=105238"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yulgary.de\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=105238"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yulgary.de\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=105238"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yulgary.de\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=105238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}